TLX Matrix Switch SNMP Traps Manual 12 Rev. E - July, 2015
TLX48 HARDWARE ALARMS (Alarm Contacts)
TLX48 Power Supply Failure Begin and Clear Contact 1
A Power Supply has failed (Begin) or is restored (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,27
Clear OID: 1,3,6,1,4,1,17658,3,14,0,28
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
TLX48 Fan Failure Begin and Clear Contact 2
A fan in the Fan Tray has failed (Begin) or is restored (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,29
Clear OID: 1,3,6,1,4,1,17658,3,14,0,30
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
TLX48 High Temperature Begin and Clear Contact 3
The system has detected a temperature that is above the preset alarm threshold (Begin) or is now below the
preset alarm threshold (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,31
Clear OID: 1,3,6,1,4,1,17658,3,14,0,32
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName